Model | DSO2D15 | DSO2D10 | DSO2C15 | DSO2C10 |
Bandwidth | 150MHz | 100MHz | 150MHz | 100MHz |
Oscilloscope channels | 2CH | 2CH | 2CH | 2CH |
Rising time | 2.4ns | 3.5ns | 2.4ns | 3.5ns |
Sample rate | 1GSa/s (single channel) 500MSa/s (two channels) | |||
Acquisition | ||||
Normal | Sample data | |||
Peak-to-peak value | Display high frequency and random burr | |||
Average | Average waveform, times: 4, 8, 16, 32, 64, 128 | |||
High resolution | Up to 12bit | |||
Input | ||||
Input coupling | DC, AC, GND | |||
Input impedance | 1MΩ±2% ‖20pF±3pF | |||
Probe attenuation factor | 1X, 10X, 100X, 1000X | |||
Voltage rating | 300V CAT II | |||
Maximum input voltage | 300VRMS (10X) | |||
Horizontal | ||||
Waveform interpolation | (sin x)/x | |||
Maximum record length | Single channel maximum 8M | |||
Two channels maximum 4M | ||||
Horizontal scale range | 2ns/div~100s/div 1, 2, 5 step by step | |||
Time base mode | Y-T, X-Y, Roll | |||
Zero offset | ±0.5 div×minimum time base gear | |||
Vertical | ||||
Vertical resolution | 8 bits resolution, each channel samples simultaneously | |||
Vertical sensitivity | 2mV/div to 10V/div | |||
Offset range | ≥ 200mV/div, ±1V; <200mV/div ±50V | |||
Mathematical operation | +, -, ×, ÷, FFT | |||
FFT | Window: Rectangle, Hanning, Hamming, Blackman, Bartlett, Flattop | |||
Bandwidth Limit | 20MHz | |||
Bass response(-3db) | In BNC position ≤ 10Hz | |||
Trigger | ||||
Trigger type | Edge, Pulse width, Video, Slope, Overtime, Window, Pattern, Interval, Under Amp, UART, LIN, CAN, SPI, IIC | |||
Trigger level range | ±5 divisions from the center of the screen | |||
Trigger mode | Auto, Normal, single | |||
Holdoff range | 8ns~10s | |||
Measurement | ||||
Cursor | Voltage difference between cursors delta V | |||
Time difference between cursors deltaT | ||||
Reciprocal of deltaT, in Hertz (1/deltaT) | ||||
Auto measurement | frequency, period, mean, peak-to-peak, RMS, minimum, mixmum, rising time, falling time, + width, - width, base, top, middle, amplitude, overshoot, preshoot, rising edge phase difference, falling edge phase difference, + duty, - duty, period mean, PRMS, FOVshoot, ROVshoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF | |||
Digital Multimeter | ||||
Data source | CH1, CH2 | |||
Measurement type | DC RMS; AC RMS; DC | |||
Frequency meter | hardware 6 bits frequency meter | |||
Arbitrary Waveform Generator | ||||
Channel | 1 | |||
Sample rate | 200MSa/s | |||
Vertical resolution | 12 bits | |||
Maximum frequency | 25 MHz | |||
Standard waveforms | sine, square, ramp,Exp, noise, DC | |||
Arbitrary waveform | Arb1, Arb2, Arb3, Arb4 | |||
Waveform length | 8kSa | |||
General specifications | ||||
Display | 7 inch TFT 800*480 LCD | |||
Standard interface | USB Host,USB Device | |||
Dimensions(L*W*H) | 318mm*110 mm*150mm | |||
Weight | 1900g |
*From: |
Enter your email |
*Message: |
Enter your Message |