Products    >    Power Detector  >    Power Quality Analyzer  >    SA2200
  • 1000Vrms 4 (3 phase+neutral) DC Coupling Power Quality Analyzer

    Model: SA2200

    Features:   

    ●5.6 inch TFT LCD with resolution 640*480

    ●Standard compliance:IEC61000-4-30 Class A

    ●Waveform real-time display(4 voltages/4 currents)

    ●Half cycle RMS measurement (voltage and current)

    ●Measurement of harmonics can be up to 100 times

    ●Vector, Trend, Bar Graph and events table display

    ●Three-phase unbalance (voltage and current)

    ●Built-in 32G memory card

    ●WIFI communication is supported

  • Products You May Like
    • Overview
    • Specification
    • Accessories
    • Compare
    • Download
    • Send your inquiry
    • SA2200 power quality analyzer adopts DSP+ARM dual processor hardware platform and embedded operation system (uClinux), which can calculate a large number of electrical parameters and process all data quickly. The device offers extensive and powerful measurements functions to check power distribution system, so it can detect quality of power grid and electrical characteristics rapidly and conveniently. The analyzer has large-screen color LCD display interface, and easy-to-use keyboard.

      Input Connections.jpg

    • MeasurementMeasurement RangeResolutionAccuracy
      Voltage / Current /  Frequency
      Vrms(AC+DC)1~120Vrms0.001Vrms±0.1% of nominal voltage
      120Vrms~400Vrms0.01Vrms
      400Vrms~1000Vrms0.1Vrms
      Vpk1~1400Vpk0.01Vpk±0.5% of nominal voltage
      V(Crest Factor)1.0~>2.80.01±5%
      Arms(AC)10mV/A0~150A0.01A±0.1% ±0.1A
      1mV/A1~2000A0.01A±0.1% ±0.1A
      65mV/1000A10~6000A0.01A±0.1% ±0.2A
      A(Crest Factor)1~100.01±5%
      Frequency42.5~57.5(50Hz   nominal)0.01Hz±0.01Hz
      51~69(60Hz nominal)0.01Hz±0.01Hz
      320~480(400Hz nominal)0.01Hz±0.01Hz
      Dips&Swells
      Vrms1/20~200% of nominal   voltage0.01Vrms±0.2%
      Arms1/2depends on current   clamps0.01A±1%
      Harmonic(IEC61000-4-7)
      Harmonic Number1~100(50/60Hz)  1~12(400Hz)
      Harmonic Voltage %   of 0.0~100.0%0.01%±0.1% ± nx0.1%
      Harmonic Current %   of0.0~100.0%0.01%±0.1% ± nx0.1%
      THD0.0~100.0%0.01%±2.5%
      Phase-180°~180°0.1°± nx0.1°
      Power and Energy
      P,S,Q1Max.6000MW0.1kW±1% ± 10 digits
      PF & CosΦ0~10.01±0.01
      kWh,kVAh,kvarhdepends on nominal voltage and current clamps±1% ± 10 digits
      Flicker(IEC61000-4-15)
      Pst(10 min) / Plt(2 hrs)0.00~20.000.01±5%
      Unbalance
      Voltage0.0~20.0%0.1%±0.1%
      Current0.0~20.0%0.1%±1%
      Voltage Phase-360°~0°0.1°±0.1°
      Current Phase-360°~0°0.1°±0.5°
      Voltage Transient
      Vpk±6000Vpk0.01V±15%
      Vrms10~1000Vrms0.01V±2.5%
      Min.Test Time5us
      Inrush Current
      Armsdepends on current   clamps0.01A±1% ± 5 digits
      Inrush Duration1~32min selectable10ms±20ms
      Mains Signaling
      Signaling   Frequency60~3000Hz0.1Hz
      Relative V%0%~100%0.10%±0.4%
      Absolute   V3s(3s average)0.0~1000V0.1V±5% of Nominal   voltage
      Logger
      Recordinguser defined parameters for 4 phases at the same time
      MemoryData stored in TF card, 32GB
      Duration Time2 hrs to 1 year,depends on the recording items and time interval
      Interval1s to 60 minutes
      General Characteristic
      Display5.6 inch TFT LCD with resolution 640*480
      InterfaceUSB Host,LAN,WIFI
      Wire Combinations1Ø+NEUTRAL,1Ø SPLIT PHASE,1Ø IT NO NEUTRAL,3Ø WYE,
           3Ø DELTA, 3Ø IT, 3Ø HIGH LEG, 3Ø OPEN LEG, 
          2-ELEMENT, 2 1/2-ELEMENT
      Electrical SafetyIEC61010-1 ,Safety Degree: 600V CAT IV  1000V CAT III
      Dimensions270mm*190mm*66mm
      Weight2kg

    • Model SA2100SA2200
      IEC61000-4-30 standard compliance Class S Class A, Ed.3
      Measurement   ItemsAC/DCYY
      Voltage/CurrentYY
      Frequency 50Hz,60Hz,400Hz50Hz,60Hz,400Hz
      Dips /swellYY
      Harmonics1-50th  (50/60Hz) 1-100th (50/60Hz)
      Power / EnergyYY
      UnbalanceYY
      MonitorYY
      InrushYY
      FlickerYY
      Transients 20kS/s 200kS/s 
      LoggerYY
      Mains signalingNOY
      Wave Recording NOY
      Input Characteristics Channel        (Voltage/Current)4/4
      Voltage Range1-1000Vrms, 6000V transient   voltage
      Current Rangedepends on supplied current   clamp
      StorageMicro   SD card
           (build-in)
      8GB32GB
      BatteryCapacity/LifeNI-MH, 3800mAh/>7hLithium ion,   5200mAh/>8h
      Time   SynchronizationGPS/Beidou NO (option)
      CommunicationInterfaceUSB Host, LANUSB Host, LAN, WIFI                               
      WIFI AppNO (option)
      General   CharacteristicScreen5.6' TFT LCD /320*2405.6' TFT LCD /640*480
      Language9-   Chinese, English,French, German,Korean, Polish,Portuguese, Spanish, Turkish14-Chinese,   English,French, German, Italian,Japanese, Korean,   Polish,Portuguese(Brazil/Portugal), Russian,Spanish (Latin/Spain), Turkish
      Dimension/Weight262× 173×66 mm/1.6kg270 ×   190×66mm/2.0kg 
      Wire Combinations1Ø+NEUTRAL,1Ø   SPLIT PHASE,1Ø IT NO NEUTRAL,3Ø WYE,3Ø DELTA, 3Ø IT, 3Ø HIGH LEG, 3Ø OPEN   LEG, 2-ELEMENT, 2 1/2-ELEMENT
      Electrical SafetyIEC61010-1 ,Safety Degree:   600V CAT IV    1000V CAT III
    • SA2200-20211011.pdf