Model | MSD-3606 | ||||
Channel | CH1&CH2 | CH1&CH2 | CH1&CH2 | CH3 | |
Output ratings | 0~30V/0~6A; | 0~60V/0~6A; | 0~30V/0~12A; | 0.1~5V/3A | |
Voltage | Line regulation | ≤0.01%+3mV | |||
Load regulation | ≤0.01%+5mV (rating current≤6A); ≤0.01%+8mV (rating current≤12A) | ||||
Ripple & Noise | ≤5mV rms(5Hz~1MHz);≤50mVpp(20Hz~20MHz) | ||||
Recovery time | ≤100us(50% load change,minimum load 0.5A) | ||||
Current | Line regulation | ≤0.2%+3mA | |||
Load regulation | ≤0.2%+3mA | ||||
Ripple & Noise | ≤3mA rms | ||||
Tracking Operation | Tracking error | ≤0.5%+10mV of the master | |||
Series regulation | ≤300mV | ||||
Ripple & Noise | ≤10mVrms(5Hz~1MHz); ≤100mVpp(20Hz~20MHz) | ||||
Output On/Off Response Time | Voltage up (10%~90%) | ≤100ms(≤95% rating load) | |||
Voltage down(90%~10%) | ≤100ms (≥10% rating load) | ||||
OVP Accuracy | ±(0.5% of reading+0.5V) | ||||
Meter | Type | 3½ digits 0.39" LED display | |||
Accuracy | ±(0.5% of reading +2 digits) | ||||
Resolution | 100mV/10mA | ||||
Protection | OVP,OTP,OLP,reverse polarity protections | ||||
Remote control | Output On/Off | ||||
Fan noise | ≤50dB | ||||
Temperature co-efficient | Voltage:≤100ppm/℃+3mV | ||||
Insulation | Between chassis and output terminal:≥100MΩ/1000VDC | ||||
Power source | AC 115V/230V±15%,50/60Hz | ||||
Accessories | Operation manual ×1, Power cord ×1 | ||||
Dimension | 310(D)×250(W)×150(H)mm | ||||
Weight | 5.5kg |